CATEGORY:    TECHNICAL

ATTENTION:   ALL DMC DEALERS/SERVICE MANAGERS

SUBJECT:     OBSTRUCTION OF FOOTWELL VENTS


In the event of poor heater/air conditioning output from the footwell
vents, check the following points:

1.  Ensure that the driver's side footwell vent is not obstructed
    by either the tunnel carpet or the main wiring harness.
    Tuck or glue the carpet beneath the vent and route the
    harness securely over the vent outlet as necessary.

2.  Ensure that the passenger's side footwell vent is not
    obstructed by the tunnel carpet.  Tuck and glue the carpet
    down beneath the vent.

Please inform all personnel accordingly.



Lutz Feuerabendt
Technical Service Manager

LF:mc



















                                                           Issued 10/26/81